iso file download
INTERNATIONALSTANDARDISO10155:1995 TECHNICAL CORRIGENDUM 1 Published 2002-02-15 Stationary source emissions -- Automated monitoring of mass concentrations of particles Performance characteristics, test methods and specifications TECHNICAL CORRIGENDUM 1 Emissions de sources fixes - Controle automatique des concentrations en masse de particules -- Caracteristiques de fonctionnement, modes operatoires d'essai et spécifications RECTIFICATIFTECHNIQUE1 Technical Corrigendum 1 to International Standard IsO 10155:1995 was prepared by Technical Committee IsO/TC 146, Air quality, Subcommittee Sc 1, Stationary source emissions. Page 9 In annex A, clause A.3 Determination of the confidence interval for the linear regression Delete equation (A.11) and replace with: S SxxSyy ICS 13.040.40 Ref.No.ISO 10155:1995/Cor.1:2002(E) @IsO 2002 - All rights reserved Printed in Switzertand No reproduction or networking permitted without license from IHS Not for Resale 4851903 0606558 612 INTERNATIONAL ISO STANDARD 10155 First edition 1995-04-01 Stationary source emissions - Automated monitoring of mass concentrations of particles - Performance characteristics, test methods and specifications Emissions de sources fixes -- Controle automatique des concentrations en massedeparticules- Caracteritisques defonctionnement, modes opératoires d'essai et spécifications ISO Reference number ISO 10155:1995(E) Provided by IHS under licen se with ISC Noreproduction or networking permitted without license from IHS Not for Resale 4851903 0606559 559 ISO10155:1995(E) Contents Page Scope 2 Normative references 3 Definitions 2 4 Measurement system components 3 4.1 Sampling and analytical components 3 4.2 Data recorder 3 5 Installation criteria 3 5.1 Sampling location 3 5.2 Environmental conditions System performance specifications 4 6.1 Response time 4 6.2 Zero drift 4 6.3 Span 5 6.4 Span drift 5 6.5 Calibration specifications 5 7 Test procedures to validate specifications 5 7.1 Response time test 5 7.2 Zero and span setting in the field 6 7.3 System calibration 6 Annexes A Statistical treatment of data 8 B Possible sampling configurations 13 c Test data forms 14 D Example of calculations 16 ISO1995 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm,without permission in writing from the publisher. InternationaiOrganizationforStandardization Case Postale 56: CH-1211Geneve 20: Switzerland Printed in Switzerland ational Organization for Standardizat Provided by IHS under license with IS Not for Res

.pdf文档 ISO 10155 1995 Stationary source emissions — Automated monitoring of mass concentrations of particles — Performance characteristics, test methods and specifications

文档预览
中文文档 24 页 50 下载 1000 浏览 0 评论 309 收藏 3.0分
温馨提示:本文档共24页,可预览 3 页,如浏览全部内容或当前文档出现乱码,可开通会员下载原始文档
ISO 10155 1995 Stationary source emissions — Automated monitoring of mass concentrations of particles — Performance characteristics, test methods and specifications 第 1 页 ISO 10155 1995 Stationary source emissions — Automated monitoring of mass concentrations of particles — Performance characteristics, test methods and specifications 第 2 页 ISO 10155 1995 Stationary source emissions — Automated monitoring of mass concentrations of particles — Performance characteristics, test methods and specifications 第 3 页
下载文档到电脑,方便使用
本文档由 人生无常 于 2024-10-03 01:15:16上传分享
友情链接
站内资源均来自网友分享或网络收集整理,若无意中侵犯到您的权利,敬请联系我们微信(点击查看客服),我们将及时删除相关资源。